Division 04 · PPD

Project Planning & Design

Project Planning & Design (PPD) focuses on the preliminary design of sites and buildings. Candidates should demonstrate an understanding of design concepts, sustainable and environmental design, universal design, and other governing codes and regulations.

Passed
09/19/22

Study recommendations

  • The exam is 4 hours and 5 minutes long and contains 100 questions.
  • The exam consists mostly of multiple-choice questions, with approximately 15% drag-and-place, hotspot, and calculation questions.
  • Spend 2 hours on the first 80 standalone questions, take a break, and then spend the next 2 hours on the two case studies.
  • Study building structures, including seismic and wind loads and concrete, masonry, and steel frames.
  • Do not study MEP systems too extensively, as they are tested more thoroughly on the PDD exam.

Exam contents (you must know)

01

Environmental Conditions & Context

Design for Different Climates

  • Cold: use a compact form and high thermal mass, orient the building south, and use evergreen trees to block winter winds.
  • Temperate: orient the long façade south and use deciduous trees on the south side to provide shade during summer.
  • Hot Arid: use high thermal mass, shade openings, use evaporative cooling, and consider a water feature.
  • Hot Humid: provide adequate cross-ventilation and use low thermal mass.

Diagrams

  • Sun chart: know how to find altitude and azimuth at a specific time and date.
  • Psychrometric chart: know how to find dry-bulb temperature, wet-bulb temperature, and relative humidity.

Sustainability

  • Understand the embodied energy of different building materials.
  • Indoor air quality: VOCs, formaldehyde, and other contaminants.

02

Codes and Regulations

Exit Requirements — Exceptions Apply

  • 1–49 occupants require 1 exit; 50–500 require 2 exits; 501–1,000 require 3 exits; and 1,001 or more require 4 exits.
  • Required exit separation: one-half of the diagonal, or one-third of the diagonal when fully sprinklered.
  • Egress width requirements: stairs require 0.3 inches per occupant, or 0.2 inches when fully sprinklered.
  • Other egress elements require 0.2 inches per occupant, or 0.15 inches when fully sprinklered.

ADA Requirements

  • Ramp slope: 1:12 maximum; rise: 30 inches maximum; run: 30 feet maximum.
  • Accessible path width: 36 inches minimum; 32 inches is allowed for a maximum length of 24 inches.
  • Turning space: 60 by 60 inches minimum.
  • Landing: 60 inches minimum.
  • Cane detection zone: provide a 27-inch-high rail when the clear height is less than 80 inches.
  • Threshold height: 1/4 inch maximum; 1/2 inch is allowed with a 1:2 bevel.

03

Building Systems, Materials & Assemblies

Air and Vapor Barriers

  • Wall: usually placed on the warmer side.
  • Roof: usually placed below rigid insulation.
  • Slab on grade: usually placed above rigid insulation.
  • The ultimate goal is to prevent condensation buildup.

Thermal Conductivity

  • k = thermal conductivity per inch; U = thermal transmittance; R = thermal resistance; R = 1/U.
  • Know how to calculate the total R-value of a wall or window assembly.
  • SHGC = solar heat gain coefficient.

Building Materials

  • Know the spans of different materials, including dimensional lumber, glulam, flat plate, waffle slab, open-web steel joists, and steel trusses.

Foundation Systems

  • Poor bearing conditions: use friction piles, piers, or caissons.
  • Good bearing conditions: use spread footings.

04

Project Integration of Program & Systems

Types of Fire Sprinklers

  • Pre-action: prevents unnecessary water damage to sensitive materials.
  • Deluge: used in high-hazard areas.
  • Dry pipe: used when sprinkler piping is subject to freezing.
  • Wet pipe: typical when special conditions do not apply.

Structural

  • Design for seismic loads: avoid discontinuous shear walls, soft stories, and reentrant corners.
  • Design for wind loads: know where positive and negative pressure occur.
  • Know when to use stiffeners, bracing, and blocking.

Acoustics

  • Sound can transfer through partitions, ceilings, ducts, floors, etc.
  • Strategies include extending walls to the deck, using acoustical insulation and sealant, using resilient channels, and staggering electrical outlets.
  • STC 45 or higher: loud speech is not audible.
  • Reverberation time can be reduced by using sound-absorbing materials on ceilings, walls, and floors.

05

Project Cost & Budgeting

Value Engineering

  • Know how to calculate cost savings by substituting a different material.
  • Know how to select alternative programs and systems when a project exceeds its budget.

Reference diagrams

Accessible door maneuvering clearance diagrams
Accessible Door Maneuvering Clearances
Roof-to-wall air and vapor barrier detail
Roof-to-Wall Air and Vapor Barrier Detail
Door handing diagrams
Door Handing Diagrams
Drain waste and vent plumbing diagram
Drain, Waste and Vent System
Galvanic series showing noble and active metals
Galvanic Series
Diagram showing the organization of a project manual
Project Manual Organization
Structural steel shape reference diagram
Structural Steel Shapes
Photometric light distribution curve
Photometric Distribution Curve
Occupancy separation table
Occupancy Separation Table